Reaction tray
37℃±0.1℃, with online softare monitor the temperature
Reagent tray
Continuous 2℃~8℃ cooling within 24 hours
Stirring needle
Teflon coating to avoid cross contamination
Sample needle
Liquid level sensor function, with anti-collision function, reagent volume real-time detection
Software
User-friendly software
Cleaning needle
Independent cleaning system
Name | Unit | Quantity |
Sample cup | One | 1 |
Cuvettes | Pack(120 units) | 1 pack |
Reagent Probe | One | 1 |
Sample Probe | One | 1 |
Mixer | One | 1 |
Fuse wire | One | 1 |
Halogen lamp | One | 1 |
Overall Performance | Model | BK-400(CRYSTAL) |
Type | Discrete, fully automatic | |
Throughput | 300T/H | |
Analysis Method | End-point, Fixed-time,Rate | |
Certification | CE, FDA, ISO9001, ISO14001, ISO13485 | |
Sample unit | Sample Settings | 60 sample positions, including calibration, quality control and emergency |
Sample Volume | 2ul ~70ul (0.1ul stepping) | |
Sample Probe | Teflon coating probe, with liquid level sensor, with anti-collision function | |
Probe cleaning | Automatic washing both interior and exterior | |
Analysis Items | Analyzing maximally 45 items at the same time | |
Reagent unit | Reagent Position | 45 low-temperature refrigerated reagent position |
Reagent Volume | 20ul ~350ul (1ul stepping), supporting reagent from different brand | |
Temperature Control | Continuous 2℃~8℃ cooling within 24 hours | |
Reagent Probe | Teflon coating probe, with liquid level sensor,withanti-collision function. | |
Probe cleaning | Automatic washing both interior and exterior | |
Reaction unit | Temperature Control | 37℃±0.1℃, with online software monitor the temperature |
Cuvettes | 120 reusable reaction cuvettes (optical path length 6mm) | |
Mixer | After injecting reagent and sample, blending immediately | |
Washing | Automatic water cleaning and drying system | |
System Adjustment | System can record the blank value and get more accurate result by deducting blank base value of each cuvette | |
Optical System | Light Source | 12V/30W halogen-tungsten lamp, 2000 hours |
Receiver | 8 precision photo receivers | |
Wavelength Range | 340, 405, 450, 510, 546, 578, 630, 700mm | |
Linear Range | 0.000~2.500Abs | |
Calibration and QC | Calibration | One-point, two-point, multi-point, factor |
Quality Control | Inserting quality control at random, with reaction curve can check each test items clearly | |
Software | Emergency Function | Emergency sample can be placed in the sample tray at any time |
Software | Windows 7 /8/10 or above, LIS system available | |
Data Processing | Having reaction curve detection and data display function in the whole process | |
Others | Power Supply | 110/220V±10%, 50/60Hz |
External Size(W*D*H) | 1020mm*830mm*1200mm | |
Package Size(W*D*H) | 1168*908*1288mm | |
Net/Gross Weight | 130kg/185kg |
①. 60 Sample positions.
②. 45 Reagent positions.
③. 120 Reaction cuvettes.
④. 300 Tests / Hour.